Analysis Of Motor Chiller Safety System In Store Building
DOI:
https://doi.org/10.58471/esaprom.v1i01.1403Keywords:
System, safety, motor, chillerAbstract
Security of the chiller is very necessary, especially to protect the motor from interference so that it can also protect the chiller from damage that occurs, in addition to protecting the surrounding environment and living things (humans). Disturbances that arise in the chiller can be caused by current and voltage, unstable loads on the motor or from its environment; This can cause damage to the motor, fire and death. The safety equipment used in the chiller motor safety system can be in the form of circuit breakers (MCCB and ELCB) or Phase Failure Relay (Motor Saver). MCCB is used as short circuit, overload and overcurrent protection; ELCB for leakage current; while the Motor Saver is used for safety of less/over voltage, asymmetrical voltage.
References
A. S. Ariyanto, “ANALISIS JENIS KERUSAKAN PADA BANGUNAN GEDUNG BERTINGKAT ( Studi Kasus pada Gedung Apartemen dan Hotel Candiland Semarang ),” Bangun Rekaprima, vol. 06, no. 01, 2020.
Fajrin Nur Arlisyah, Sri Sukmawati, and Anita Trisiana, “Assessment Of Green Building Based On Greenship For New Building Version 1.2 Using Fuzzy Logic,” J. Appl. Civ. Eng. Infrastruct. Technol., vol. 1, no. 1, 2020, doi: 10.52158/jaceit.v1i1.61.
Q. ZAHRO, “KAJIAN AWAL KESIAPAN GEDUNG BERTINGKAT DI JAKARTA TERHADAP BENCANA GEMPA BUMI,” J. Sains dan Teknol. Mitigasi Bencana, vol. 13, no. 2, 2019, doi: 10.29122/jstmb.v13i2.3359.
A. Siricharoenpanich, S. Wiriyasart, R. Prurapark, and P. Naphon, “Effect of cooling water loop on the thermal performance of air conditioning system,” Case Stud. Therm. Eng., vol. 15, 2019, doi: 10.1016/j.csite.2019.100518.
M. Pereira, A. Tribess, G. Buonanno, L. Stabile, M. Scungio, and I. Baffo, “Particle and carbon dioxide concentration levels in a surgical room conditioned with a window/wall air-conditioning system,” Int. J. Environ. Res. Public Health, vol. 17, no. 4, 2020, doi: 10.3390/ijerph17041180.
E. Yuniarti, A. Majid, and F. Faisal, “STUDI PERLAKUAN TERHADAP TANAH UNTUK MENENTUKAN NILAI RESISTANSI DAN TAHANAN JENIS PENTANAHAN,” J. SURYA ENERGY, vol. 3, no. 2, 2019, doi: 10.32502/jse.v3i2.1516.
W. H. Chandra, I. B. A. Swamardika, and A. A. G. M. Pemayun, “Analisis Penggunaan Ddc Pada Sistem Hvac Untuk Meningkatkan Penghematan Konsumsi Energi Di Hotel Langham District 8 Scbd Jakarta,” Spektrum, vol. 7, no. 3, 2020.
S. Riyanto, “PERANCANGAN INSTALASI LISTRIK DENGAN MENGGUNAKAN SISTEM HYBRID DAN JALA-JALA PLN PADA BANGUNAN PT. PERTAMINA EP ASSET 5 TARAKAN FIELD,” INOVTEK POLBENG, vol. 9, no. 2, 2019, doi: 10.35314/ip.v9i2.1049.
D. Feriyanto, “PERLINDUNGAN TERHADAP BAHAYA HUBUNG SINGKAT (SHORT CIRCUIT) PADA INSTALASI LISTRIK,” Aisyah J. Informatics Electr. Eng., vol. 1, no. 1, 2019, doi: 10.30604/jti.v1i1.7.
N. M. Seniari, S. Supriyatna, A. Natsir, I. A. S. Adnyani, and S. Nababan, “PELATIHAN PEMASANGAN INSTALASI LISTRIK RUMAH TANGGA YANG AMAN BAGI WARGA KELURAHAN PAGUTAN BARAT KOTA MATARAM,” Abdi Insa., vol. 6, no. 1, 2019, doi: 10.29303/abdiinsani.v6i1.219.
A. W. Hasanah et al., “Sosialisasi Keamanan Listrik Rumah Tangga di RW 08 Ciomas Permai, Bogor,” TERANG, vol. 2, no. 1, 2019, doi: 10.33322/terang.v2i1.530.
Z. Munawar, “MEKANISME KESELAMATAN, KEAMANAN DAN KEBERLANJUTAN UNTUK SISTEM SIBER FISIK,” TEMATIK, vol. 7, no. 1, 2020, doi: 10.38204/tematik.v7i1.371.
F. D. Sukardi, A. Zain, and A. Muliawan, “Prototipe Pengaman Peralatan Instalasi Listrik dan Tegangan Sentuh Bagi Manusia dengan ELCB ( Earth Leakege Circuit Breaker ),” J. Teknol. Elekterika, vol. 16, no. 2, 2019, doi: 10.31963/elekterika.v16i2.2010.
K. Mirah Mahadewi, I. G. N. Janardana, and I. W. Arta Wijaya, “ANALISIS TEGANGAN LANGKAH DAN TEGANGAN SENTUH SERTA PERENCANAAN SISTEM PEMBUMIAN PADA PEMBANGUNAN SUBSTATION VVIP DI BANDAR UDARA INTERNASIONAL I GUSTI NGURAH RAI BALI,” J. SPEKTRUM, vol. 6, no. 1, 2019, doi: 10.24843/spektrum.2019.v06.i01.p20.