Design Of A Fiber Optic Sensor-Based Respiration Monitoring System
Keywords:
SMS fiber optic sensor, Respiratory rate, Multimode, Beat Per minute (BPM)Abstract
Human breathing rate is an essential marker for assessing one's health, especially regarding respiratory issues. Precise breathing measurements are vital in medicine as they help detect problems early and devise effective treatment plans. The use of fiber optic sensors to monitor breathing offers excellent potential in health monitoring, both medically and independently. Such sensors have advantages such as ease of manufacturing, high sensitivity, compact size, and affordable cost. In this study, a Singlemode-Multimode-Singlemode (SMS) optical fiber-based breathing sensor was designed by fitting it as a belt around the abdomen to measure abdominal breathing. This SMS sensor has variations in multimode length and wavelength used. Tests were conducted in sitting and standing positions, and the results showed the best performance of the SMS sensor at a multimode length of 3.5 cm with an accuracy rate of 99.2525%, linearity of 0.9997, and sensitivity of 2.9725 Hz/dBm. In addition, the standing body position provides 96.5% accuracy with a multimode length of 3.5 cm, while the sitting position provides 96.8% accuracy with a multimode length of 2 cm.
Downloads
References
Badr, C., Elkins, M. R., & Ellis, E. R. (2002). The effect of body position on maximal expiratory pressure and flow. The Australian Journal of Physiotherapy, 48(2), 95–102. https://doi.org/10.1016/s0004-9514(14)60203-8
Cobb, W. S., Burns, J. M., Kercher, K. W., Matthews, B. D., James Norton, H., & Todd Heniford, B. (2005). Normal intraabdominal pressure in healthy adults. Journal of Surgical Research, 129(2), 231–235. https://doi.org/10.1016/j.jss.2005.06.015
Costa, R., Almeida, N., & Ribeiro, F. (2015b). Body position influences the maximum inspiratory and expiratory mouth pressures of young healthy subjects. Physiotherapy, 101(2), 239–241. https://doi.org/10.1016/j.physio.2014.08.002
D’Angelo, L. T., Weber, S., Honda, Y., Thiel, T., Narbonneau, F., & Luth, T. C. (2008). A system for respiratory motion detection using optical fibers embedded into textiles. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference, 2008, 3694–3697. https://doi.org/10.1109/IEMBS.2008.4650011
Muhamad Hatta, A. (2009). Singlemode-Multimode-Singlemode Optical Fibre Structures for Optical Sensing. https://doi.org/10.21427/D7TP5F
Pitero, M. A. de. (2019). Normal respiratory rates : Adults and children. Https://Www.Medicalnewstoday.Com/Articles/32440 9.Php.
Proceedings of the 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society : “personalized healthcare through technology” : August 20-24, 2008, Vancouver Convention & Exhibition Centre, Vancouver, British Columbia, Canada. (2008). IEEE.
Smith, I., Mackay, J., Fahrid, N., & Krucheck, D. (2011). Respiratory rate measurement: a comparison of methods. British Journal of Healthcare Assistants, 5(1), 18–23. https://doi.org/10.12968/bjha.2011.5.1.18
WHO. (2019). Monitoring Health For The SDGs.